Self-Coat Screed 

ZERO V.O.C. E.M.T. SCREEDING

 

DESCRIPTION

An Polymer based floor screed for high impact areas. 

 

PRINCIPAL CHARACTERISTICS

Floor screed.  High film builds to cover irregular surfaces.  Good impact resistance.  Suitable for floor surfaces.  Good waterproofing qualities.  Has excellent abrasion resistance ideal for vibrating structures i.e. bridges and airports, is non-toxic and ZERO H.A.P. 

 

TECHNICAL DATA

 

Colour

Cement grey can be toned to various pastel colours

Finish

 

Wood Float, metal trowel

Sheep skin roller – brush

Vehicle type

Natural Polymers

Pigments

Chrome and Iron

Solvent

Water

Cleaner

Water

Thinner

Must not be thinned

Flash point

Waterborne non-flammable

Specific gravity

2.1 Approx

Viscosity

Not relevant

% Solids by mass

Minimum 90%

% Solids by volume

Minimum 95%

Pot life

8 Hours from opening

Shelf life

Min 7 days

Spreading rate

  3 – 4 m²/l (1 coat)

 

 

 

 

APPLICATION

Supplied ready for application.  Stir contents thoroughly before application.  Clean equipment with water before touch dry state.  If the screeding is applied to thick, there will be cracks.  If it is necessary that the screeding must be a thick application, it should be done in layers.

 

 

SURFACE PREPARATION

Ensure all traces of loose friable materials; dirt, oil, and debris are removed.  Freshly cast conventional screeds must be allowed to dry thoroughly before application of SELF-COAT BIND and SCREEDING.   Bulk concrete to cure for 28 days minimum before application.  Surfaces to be primed with SELF-COAT BIND. 

 

THICKNESS

Minimum 1 mm                                 Maximum as required 

 

DRYING TIME @ 20 deg. C for 1 micrometer thickness and RH<75%>

TOUCH DRY

6 hours

OVER COAT

1-2 hours

NORMAL SERVICE

Approx 36 hours

FULL CURE

8 days

 

 

THEORETICAL SPREADING RATE

The theoretical spreading rate stated here is for DFT of 2 mm on a smooth surface for reasons of convenience and comparison.  The user must calculate the practical spreading rate.

 

REQUIREMENTS FOR STORAGE AND APPLICATION

 

PARAMETER

STORAGE (UNOPENED)

PAINT

SUBSTRATE

ENVIRONMENT

% RH

(Relative humidity)

100 % Max

 

 

Min 2 deg. C above

dew point

85% Max

Temp deg. C min

5 deg. C

5 deg. C

5 deg. C

5 deg. C

Temp deg. C max

40 deg. C

40 deg.  C

40 deg. C

40 deg. C

 

 

<<<<  Back to Products

_____________________________________________________________________

Disclaimer:

The recommendations contained herein are meant to guide the specified or the uses.  They are based on results gained from our experience and tests and are believed to be reliable.  No guarantee is implied by the recommendations contained herein since method of application, condition of use and cleanliness of the substrate prior to painting are beyond our control.